ArcelorMittal

Connectors

The hot rolled sections RZD/RZU and RH connect the intermediary AZ sheet piles to the HZM king piles to form a continuous wall. 

 

Connectors

Section Dimensions A G I W AL
h w a ay y-y z-z y-y z-z
mm mm mm mm cm2 kg/m cm4 cm4 cm3 cm3 m2/m
RZD 1661,880,5-31,520,716,2579418220,18
RZU 1661,880,5-38,320,416,1689418220,18
RH 1661,868,212,232,520,116,0835425160,19
RZD 1867,385,0-35,923,018,17811022250,19
RZU 1867,385,0-42,122,617,99211022250,19
RH 2067,379,214,236,525,220,01228833220,21
Show values in imperial units

Suitable king pile:

 

RZD 16: HZ 880 M, HZ 1080 M, HZ 1180M A-B
RZU 16: HZ 880 M, HZ 1080 M, HZ 1180M A-B
RH 16: HZ 880 M, HZ 1080 M, HZ 1180M A-B
RZD 18: HZ 1180M C-D
RZU 18: HZ 1180M C-D
RH 20: HZ 1180M C-D


 

A Cross sectional steel area
G Mass
Iy Moment of inertia about the main neutral axis y-y
Iz Moment of inertia about the main neutral axis z-z
Wy Equivalent elastic section modulus related to the neutra axis y-y
Wz Equivalent elastic section modulus related to the neutra axis z-z
AL Coating Area