Connectors
The hot rolled sections RZD/RZU and RH connect the intermediary AZ sheet piles to the HZ/HZ-M king piles to form a continuous wall.
.jpg)
Connectors
| Section | Dimensions | A | G | I | W | AL | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| h | w | a | ay | y-y | z-z | y-y | z-z | ||||
| in | in | in | in | in2 | lb/ft | in4 | in4 | in3 | in3 | in2/ft | |
| RZD 16 | 2,43 | 3,19 | - | 1,24 | 3,21 | 10,89 | 1,4 | 2,3 | 1,1 | 1,3 | 0,59 |
| RZU 16 | 2,43 | 3,19 | - | 1,51 | 3,16 | 10,82 | 1,6 | 2,3 | 1,1 | 1,3 | 0,59 |
| RH 16 | 2,43 | 2,69 | 0,48 | 1,28 | 3,12 | 10,75 | 2,0 | 1,3 | 1,5 | 1,0 | 0,63 |
| RZD 18 | 2,65 | 3,35 | - | 1,41 | 3,57 | 12,16 | 1,9 | 2,6 | 1,3 | 1,5 | 0,63 |
| RZU 18 | 2,65 | 3,35 | - | 1,66 | 3,50 | 12,03 | 2,2 | 2,6 | 1,3 | 1,5 | 0,63 |
| RH 20 | 2,65 | 3,12 | 0,56 | 1,44 | 3,91 | 13,44 | 2,9 | 2,1 | 2,0 | 1,3 | 0,69 |
Suitable king pile:
| RZD 16: | HZ 775 A-B, HZ 975 A-B, HZ 880 M, HZ1080 M, HZ 1180M A-B |
| RZU 16: | HZ 775 A-B, HZ 975 A-B, HZ 880 M, HZ1080 M, HZ 1180M A-B |
| RH 16: | HZ 775 A-B, HZ 975 A-B, HZ 880 M, HZ1080 M, HZ 1180M A-B |
| RZD 18: | HZ 775 C-D, HZ 975 C-D, HZ 1180M C-D |
| RZU 18: | HZ 775 C-D, HZ 975 C-D, HZ 1180M C-D |
| RH 20: | HZ 775 C-D, HZ 975 C-D, HZ 1180M C-D |
| A | Cross sectional steel area |
| G | Mass |
| Iy | Moment of inertia about the main neutral axis y-y |
| Iz | Moment of inertia about the main neutral axis z-z |
| Wy | Equivalent elastic section modulus related to the neutra axis y-y |
| Wz | Equivalent elastic section modulus related to the neutra axis z-z |
| AL | Coating Area |